Minimume Installation Clearance For Sheet Metal Fireplace
Minimum clearance along the bottom of shield.
Minimume installation clearance for sheet metal fireplace. 75 mm 3 in. Wood beams joists studs and other combustible material shall have a clearance of not less than 2 inches 51 mm from the front faces and sides of masonry fireplaces and not less than 4 inches 102 mm from the back faces of masonry fireplaces. Parts of the mantel assembly located along the sides of the fireplace opening which project more than 1 1 2 inches 38mm from the face of the fireplace shall have additional clearance equal to the projection extension beyond 1 1 2 inches. With the fireplace in place assemble the chimney sections and fasten them together as you do.
Shield extension beyond each side of appliance. All chimney enclosures must maintain the required minimum air space clearance of 2 50mm to the chimney. The local code may require more firestops based on the total footage so account for that in your plans. Factory built fireplaces are a prefabricated sheet metal system that relies on clearances to combustibles to operate safely.
Maximum clearance along the bottom of shield. 450 mm 18 in. There may be other factors to conform to code for clearances on the roof high wind high altitude etc that may make the minimumheight undesirable or a violation of building codes. When enclosing the chimney below the roof line a rafter radiation shield rrs must be installed at the roof level.
21 mm 7 8 in. The recommended minimum chimney height is 15 feet from the flue collar of the stove to the top of the chimney. If the stove legs provide less than 6 inches of clearance 2 to 4 inches of hollow masonry laid to pro vide air circulation with a sheet of 24 gage sheet metal between the floor and the masonry is recommended. Ul 103 type ht ul1738.
Using a piece of 24 gauge sheet metal installed on spacers 1 from an existing wall and floor will reduce stove clearances by 66 or from 36 to 12. The clearance reduction is usually measured from the rear of the stove to the original combustible wall not to the sheet metal. Minimum space between shield and combustibles. 75 mm 3 in.
Minimum installation clearances to com bustibles 50 mm 2 or as established by support assembly. Regardless of the fuel type there are common design aspects of all factory built fireplaces that must be taken into consideration when planning a diy installation. May also be installed with listed factory built fireplaces as specified in fireplace manufacturer s installation instructions and identified on the fireplace label. Minimum clearance along the top of shield at ceiling.
Metal or asbestos millboard must be installed between the brick slate or stone and the floor. 25 mm 1 in.