Minimum Roof Sheathing For N C Residential
Roof sheathing comes in grid marked 4 by 8 foot sheets and should be installed perpendicular to the frame.
Minimum roof sheathing for n c residential. Fasteners for asphalt shingles shall be galvanized steel stainless steel aluminum or copper roofing nails minimum 12 gage 0 105 inch 3 mm shank with a minimum 3 8 inch diameter 9 5 mm head complying with astm f1667 of a length to penetrate through the roofing materials and not less than 3 4 inch 19 1 mm into the roof sheathing. Never attach roof sheathing with staples. Roofs shall be covered withmaterialsassetforthinsectionsr904andr905 classa b or c roofing shall be installed in areas designated by law as requiring their use or when the edge of the roof is less than 3 feet 914 mm from aproperty line classesa bandcroofing requiredtobelistedbythissectionshallbetestedinaccordance with ul 790 or astm e 108. 7 1 r oofing 7 12 10 roof sheathing installation key issues n insufficient fastening can lead to total building failure in a windstorm.
That will suffice on a roof with rafters set 16 inches apart with minimal roof loads. Energy conservation code ncecc 301 n. North carolina state building code. Designer of record is responsible to ensure all roofing projects conform to the minimum requirement of the code.
Walls need to be insulated to a minimum of r 20 if the insulation is between the studs or r 15 r 5 if the insulation is a combination of insulation between the studs and a continuous layer of exterior insulation in zones 3 or 4. The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process. Loads will vary with the. 8d ring shank nails should be used instead.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures. If your local building authority has a rafter spacing code you may not space rafters wider than required by code. Sheathing should be a minimum of 19 32 inch thick. Typical rafter spacing codes will specify a minimum spacing of 16 inches 19 2 inches or 24 inches.
N fastener spacing. Roof sheathing installation 1 of 3 home builder s guide to coastal construction technical fact sheet no. The typical thickness range for sheathing is 3 8 to 3 4 inch. Design calculations the designer is record is responsible for performing all.
Rafters must be strong enough to hold the roof sheathing and the shingles. Roofs or ceilings need to be insulated to a minimum of r 38 in zone 3 or r 49 in zone 4.