This applies whether the waterproofing is a polymeric single ply membrane a reinforced bitumen membrane or another type listed in bs 6229 2018 the code of practice for flat roofs with continuously supported flexible waterproof coverings.
Minimum fall for flat roof uk. If flat roofs are to work well they have to have a slope known as a fall to shed rainwater. Firrings it is normal practice for the joists of a flat roof to be set level thus creating a perfectly level ceiling. Good practice guidance recommends that flat roofs defined as 10ยบ should not be completely flat and should be designed with adequate finished falls to ensure the completed roof drains freely. To achieve a 1 80 fall the code of practice says that the roof should be designed for a fall of 1 40 1 44 to account for construction tolerances deviation in the roof deck and.
As opposed to old built up felt roofing with joins new single ply waterproof membranes are now most commonly used. According to bs 6229 bs 8217 flat roofs should be designed with minimum falls of 1 40 to ensure a finished fall of 1 80 can be achieved allowing for any inaccuracies in the construction. It takes the manufacturer s recommendations the unique conditions of the roof as well as the skills and the expertise of the installer to arrive at the right slope. The recommended minimum fall for a flat roof is 1 80 0 72.
The fall of the roof may be created in the structure itself by laying the supporting beams or joists at a slope giving a sloping soffit or by installing tapered beams with horizontal soffits. This applies to general roof areas along with any internal gutters. The correct minimum fall of a flat roof should be 1 60 by design to acheive 1 80 with deflection ie sagging over time but with flat roofs with a gutter and no internal outlets to worry about over whelming the greater the fall the better. In general the minimum slope for a flat roof is 1 0 but as stated earlier this is only possible in theory.
6m 60 100mm difference between top and bottom cambridgeroofer 6 oct 2008 8. There are two types of flat roof. Sika limited strongly recommends that in accordance with bs 6229 2018 flat roofs with continuously supported flexible waterproof coverings code of practice and the spra code of practice a minimum 1 80 finished fall is recommended to both the general area of the roof and to any. As the single ply roofing association spra points out this type of flat roofing is strong durable completely sealed and usually lasts at least 25 30 years.
Cold roofs and warm roofs. Normally 1 80 0 72 is the recommended minimum angle for a slope and this is universal across the vast majority of flat roofing systems regardless of the materials that they incorporate.